{"id":395,"date":"2026-10-14T18:51:50","date_gmt":"2026-10-14T10:51:50","guid":{"rendered":"https:\/\/www.eoil.com\/?p=395"},"modified":"2026-10-14T18:51:52","modified_gmt":"2026-10-14T10:51:52","slug":"laser-cutting-machine-maintenance-care-of-lenses-nozzles-and-the-optical-system","status":"publish","type":"post","link":"https:\/\/www.eoil.com\/index.php\/en\/laser-cutting-machine-maintenance-care-of-lenses-nozzles-and-the-optical-system\/","title":{"rendered":"Laser Cutting Machine Maintenance: Care of Lenses, Nozzles, and the Optical System"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The processing capability and operating cost of a laser cutting machine depend heavily on the level of daily maintenance. Of two identical machines, one may still cut with consistent quality after three years while the other suffers frequent incomplete cuts, rough edges, and power degradation. The difference is usually not the brand of the machine but whether maintenance has been carried out properly. Optical lenses, cutting nozzles, the water-cooling system, guide rails, and the dust-extraction system are the five priority areas. Based on Minshuo Smart Manufacturing&#8217;s practical equipment-management experience, this article explains the key maintenance points and intervals for laser cutting machines.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">1. Why Maintenance Directly Affects Cutting Quality and Cost<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Laser cutting cost consists of three parts: energy, gas consumables, and wear parts. The replacement interval of wear parts is closely tied to maintenance quality:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Maintenance level<\/th><th>Lens life<\/th><th>Nozzle life<\/th><th>Cutting-quality stability<\/th><th>Overall cost per part<\/th><\/tr><\/thead><tbody><tr><td>Disciplined maintenance<\/td><td>3-6 months<\/td><td>2-4 months<\/td><td>Stable<\/td><td>Baseline<\/td><\/tr><tr><td>Average maintenance<\/td><td>1-2 months<\/td><td>1-2 months<\/td><td>Fluctuating<\/td><td>15%-30% higher<\/td><\/tr><tr><td>Neglected maintenance<\/td><td>Replacement needed within weeks<\/td><td>Replacement needed within weeks<\/td><td>Frequent abnormalities<\/td><td>More than 50% higher<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Many companies treat lenses and nozzles as consumables to be replaced only when they fail. In reality, <strong>a contaminated lens attenuates laser energy; the operator then increases power to cut through, which raises electricity consumption, further degrades the lens, and keeps the machine running overloaded for long periods.<\/strong> This is a classic vicious cycle.<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Minshuo Smart Manufacturing reminder:<\/strong> Our records show that on the same machine, average monthly nozzle consumption under disciplined maintenance is more than 40% lower than under neglected maintenance, and gas consumption is 10%-15% lower. Maintenance is not a cost; it is a direct cost-control measure.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">2. Maintenance Schedule Overview<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Interval<\/th><th>Maintenance content<\/th><\/tr><\/thead><tbody><tr><td>Every shift (8 hours)<\/td><td>Clean the protective lens, check nozzle condition, clear slag from the cutting area, check gas pressure, drain condensate from the air receiver<\/td><\/tr><tr><td>Weekly<\/td><td>Check nozzle concentricity, clean guide rails and racks, check chiller water level and temperature, clean dust off extraction filters<\/td><\/tr><tr><td>Monthly<\/td><td>Inspect the focusing lens, verify focus position, check chiller water quality, check gas-line fittings for leaks, check machine feet and leveling<\/td><\/tr><tr><td>Quarterly<\/td><td>Replace chiller deionized water and filters, inspect the full beam path, verify machine accuracy, check electrical-cabinet cleanliness and cooling<\/td><\/tr><tr><td>Annually<\/td><td>Replace aging gas and water hoses, fully calibrate the machine, inspect the laser-source cooling circuit, professionally service the cutting head<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">These intervals are general recommendations and should be adjusted according to running hours, material types, and workshop environment. For machines cutting high-dust materials such as galvanized sheet and aluminum, intervals should be shortened by 30%-50%.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">3. Optical Lens Maintenance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A laser cutting machine has three critical optical lenses with different maintenance requirements and replacement intervals:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Lens type<\/th><th>Location<\/th><th>Common contamination<\/th><th>Reference replacement interval<\/th><\/tr><\/thead><tbody><tr><td>Protective lens<\/td><td>Lowest position in the cutting head, closest to the workpiece<\/td><td>Spatter, fume, oil mist<\/td><td>3-8 weeks, depending on conditions<\/td><\/tr><tr><td>Focusing lens<\/td><td>Inside the cutting head<\/td><td>Moisture, fine fume<\/td><td>6-12 months<\/td><\/tr><tr><td>Collimating lens<\/td><td>Upper part of the cutting head, after the fiber input<\/td><td>Moisture, oil mist<\/td><td>12-24 months<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.1 Daily Inspection of the Protective Lens<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The protective lens should be inspected <strong>once per shift<\/strong>:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Stop the machine and confirm the laser is switched off.<\/li>\n\n\n\n<li>Remove the protective lens holder from the lower end of the cutting head.<\/li>\n\n\n\n<li>Examine the lens surface under strong light or a dedicated inspection lamp.<\/li>\n\n\n\n<li>Check for fume spots, spatter marks, scratches, and coating damage.<\/li>\n\n\n\n<li>Check whether the sealing ring is deformed, aged, or damaged.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Judgment criteria:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Condition<\/th><th>Action<\/th><\/tr><\/thead><tbody><tr><td>Loose dust on the surface<\/td><td>Clean properly and continue using<\/td><\/tr><tr><td>Fume spots but normal light transmission<\/td><td>Clean, monitor, and record service time<\/td><\/tr><tr><td>Spatter marks, obvious scratches, or coating loss<\/td><td>Replace immediately<\/td><\/tr><tr><td>Aged or damaged sealing ring<\/td><td>Replace the sealing ring together with the lens<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.2 Correct Lens Cleaning Procedure<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Lens cleaning is the step most prone to error. Damage caused by incorrect cleaning is often greater than the damage caused by not cleaning at all.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Correct steps:<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Blow off loose dust with an air blower or dry nitrogen. <strong>Never wipe a lens that still has dust on it.<\/strong><\/li>\n\n\n\n<li>Use analytical-grade anhydrous ethanol or a dedicated lens-cleaning solution.<\/li>\n\n\n\n<li>Use dedicated lens tissue or a cotton swab with a small amount of cleaning solution.<\/li>\n\n\n\n<li>Wipe in a spiral from the center toward the edge, <strong>in one direction only\u2014do not scrub back and forth.<\/strong><\/li>\n\n\n\n<li>Complete the wipe in a single pass and do not reuse dirty lens tissue.<\/li>\n\n\n\n<li>Inspect under a lamp to confirm no residue remains.<\/li>\n\n\n\n<li>Wear gloves during assembly to avoid touching the lens surface with bare fingers.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Prohibited practices:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Do not wipe with ordinary paper towels, cotton cloth, or coarse tissue.<\/li>\n\n\n\n<li>Do not blow on the lens with your mouth; saliva contaminates the surface.<\/li>\n\n\n\n<li>Do not touch the lens surface with bare hands.<\/li>\n\n\n\n<li>Do not use water-containing alcohol or industrial-grade alcohol.<\/li>\n\n\n\n<li>Do not use the same piece of lens tissue for multiple lenses.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">3.3 Effect of Lens Contamination on Cutting Quality<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Contamination level<\/th><th>Symptom<\/th><th>Effect<\/th><\/tr><\/thead><tbody><tr><td>Light<\/td><td>Slight power attenuation<\/td><td>Slower cutting on thick sheet<\/td><\/tr><tr><td>Moderate<\/td><td>Rough cut edge and more dross<\/td><td>Lower yield<\/td><\/tr><tr><td>Severe<\/td><td>Incomplete cuts, piercing failure<\/td><td>Production stop; lens may already be burned<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Minshuo Smart Manufacturing experience:<\/strong> We once handled a case in which a customer reported that the same program suddenly could not cut through 8 mm carbon steel. Inspection found a spatter spot about 0.5 mm in diameter on the protective lens, causing more than 20% beam-energy loss. Replacing the lens solved the problem immediately. If this detail is overlooked, the operator may keep increasing power and reducing speed, eventually burning the nozzle or damaging the cutting head.<\/p>\n<\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">4. Nozzle Maintenance and Replacement<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">4.1 Function of the Nozzle and Common Damage<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The nozzle guides the assist gas, stabilizes the gas flow, and protects the lens. Common damage includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Orifice wear, enlargement, or oval deformation.<\/li>\n\n\n\n<li>Spatter adhering to the orifice.<\/li>\n\n\n\n<li>Scratches or deformation on the inner wall.<\/li>\n\n\n\n<li>Cracked ceramic body or damaged sealing face.<\/li>\n\n\n\n<li>Damaged threads preventing proper tightening.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">4.2 Nozzle Inspection Points<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Inspection item<\/th><th>Method<\/th><th>Acceptance criterion<\/th><\/tr><\/thead><tbody><tr><td>Orifice diameter<\/td><td>Pin gauge or comparison under magnification<\/td><td>Replace when more than 10% above nominal<\/td><\/tr><tr><td>Orifice roundness<\/td><td>Observation under magnification<\/td><td>Replace if clearly oval or chipped<\/td><\/tr><tr><td>Inner-wall cleanliness<\/td><td>Inspection under strong light<\/td><td>Clean or replace if deposits are present<\/td><\/tr><tr><td>Concentricity<\/td><td>Dot-marking test or tape test<\/td><td>Beam spot concentric with the orifice<\/td><\/tr><tr><td>Sealing face<\/td><td>Visual inspection<\/td><td>No indentations or deformation<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">4.3 Nozzle Concentricity Calibration<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nozzle concentricity directly affects cutting quality and gas utilization. Calibration procedure:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Move the cutting head to the appropriate height above the sheet.<\/li>\n\n\n\n<li>Apply a strip of masking tape or dedicated detection tape.<\/li>\n\n\n\n<li>Fire a dot at low power for a very short duration.<\/li>\n\n\n\n<li>Remove the tape and observe the position of the beam spot.<\/li>\n\n\n\n<li>If the spot is off-center relative to the orifice, adjust the nozzle position with the adjusting screws on the cutting head.<\/li>\n\n\n\n<li>Fire another dot to verify, repeating until the spot and orifice are concentric.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Effect of concentricity deviation:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Deviation<\/th><th>Effect<\/th><\/tr><\/thead><tbody><tr><td>Less than 0.1 mm<\/td><td>Essentially no effect<\/td><\/tr><tr><td>0.1-0.2 mm<\/td><td>Reduced cut-edge quality and higher gas consumption<\/td><\/tr><tr><td>More than 0.2 mm<\/td><td>Severe dross, burn-through on thin sheet, sharply reduced nozzle life<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Verify concentricity <strong>at least once a week<\/strong>. After replacing a nozzle or after a head collision, recalibration is mandatory.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">4.4 Nozzle Cleaning and Replacement Principles<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Clean spatter from the orifice regularly, avoiding hard tools that scratch the inner wall.<\/li>\n\n\n\n<li>The nozzle is a wear part; <strong>do not wait until the orifice is visibly deformed to replace it.<\/strong><\/li>\n\n\n\n<li>Keep nozzles with the correct orifice size for each sheet thickness and gas type.<\/li>\n\n\n\n<li>Maintain a nozzle log recording installation date and service hours.<\/li>\n\n\n\n<li>Recalibrate concentricity after every nozzle change.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">5. Cutting Head and Other Wear Parts<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Component<\/th><th>Maintenance point<\/th><th>Interval<\/th><\/tr><\/thead><tbody><tr><td>Ceramic ring or body<\/td><td>Check for cracks and deformation; confirm proper seating after installation<\/td><td>Every shift<\/td><\/tr><tr><td>Capacitive sensor<\/td><td>Clean the sensing ring and check signal stability<\/td><td>Weekly<\/td><\/tr><tr><td>Collision protection device<\/td><td>Check reset function and sensitivity<\/td><td>Monthly<\/td><\/tr><tr><td>Assist-gas path<\/td><td>Check for blockage and leaks<\/td><td>Monthly<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">6. Water-Cooling System Maintenance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The water-cooling system directly affects heat dissipation for the laser source, lenses, and cutting head, and it is the most easily neglected part of maintenance.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.1 Water Quality Requirements<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Parameter<\/th><th>Requirement<\/th><th>Notes<\/th><\/tr><\/thead><tbody><tr><td>Conductivity<\/td><td>&lt;= 10 \u03bcS\/cm (0.5-10 recommended)<\/td><td>Lower is better; replace the water if it rises noticeably, for example above 20 \u03bcS\/cm<\/td><\/tr><tr><td>Water temperature<\/td><td>22-28\u00b0C<\/td><td>25\u00b0C is a common setpoint<\/td><\/tr><tr><td>Water level<\/td><td>Between high and low marks<\/td><td>Check weekly<\/td><\/tr><tr><td>Cleanliness<\/td><td>Free of impurities and algae<\/td><td>Use deionized or purified water<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Never use tap water or well water.<\/strong> Calcium and magnesium ions in water form scale in the heat exchanger and piping, reducing cooling capacity and, in severe cases, causing high-temperature alarms or damage to the laser source.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">6.2 Common Problems<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Problem<\/th><th>Cause<\/th><th>Countermeasure<\/th><\/tr><\/thead><tbody><tr><td>Water temperature too high<\/td><td>Dust on the condenser, insufficient refrigerant, high ambient temperature<\/td><td>Clean the condenser, top up refrigerant, improve ventilation<\/td><\/tr><tr><td>Large temperature fluctuation<\/td><td>Low water level, pump fault<\/td><td>Add deionized water, inspect the pump<\/td><\/tr><tr><td>Cloudy water<\/td><td>Water not replaced for a long time, filter exhausted<\/td><td>Replace water and filters<\/td><\/tr><tr><td>Leaking piping<\/td><td>Aged fittings, cracked hoses<\/td><td>Replace hoses and fittings<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">6.3 Winter Freeze Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When the workshop temperature approaches 0\u00b0C, add a suitable antifreeze to the water in the correct proportion or keep the machine running. Water expands when it freezes and will crack the heat exchanger and water circuit, causing irreversible major damage.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">7. Guide Rails, Racks, and Drive Systems<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Location<\/th><th>Maintenance content<\/th><th>Interval<\/th><\/tr><\/thead><tbody><tr><td>Linear guide rails<\/td><td>Clean the surface and apply dedicated rail lubricant<\/td><td>Clean every shift, lubricate weekly<\/td><\/tr><tr><td>Racks<\/td><td>Remove chips and oil contamination, apply grease<\/td><td>Weekly<\/td><\/tr><tr><td>Sliders<\/td><td>Check for abnormal noise and play<\/td><td>Monthly<\/td><\/tr><tr><td>Servo motors<\/td><td>Check temperature, noise, and vibration<\/td><td>Monthly<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Important note:<\/strong> Dust and chips from carbon steel cutting adhere readily to guide rails and racks. Leaving them in place accelerates slider wear and degrades cutting accuracy. Clean the rails every shift when cutting carbon steel.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">8. Dust Extraction and Fume System<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Component<\/th><th>Maintenance content<\/th><th>Interval<\/th><\/tr><\/thead><tbody><tr><td>Extraction filter cartridges<\/td><td>Remove surface dust; replace when necessary<\/td><td>Inspect weekly, replace every 1-3 months<\/td><\/tr><tr><td>Dust collection bin<\/td><td>Empty accumulated dust to prevent secondary dispersion<\/td><td>Weekly<\/td><\/tr><tr><td>Ducting<\/td><td>Check for blockage and air leakage<\/td><td>Monthly<\/td><\/tr><tr><td>Fan<\/td><td>Check bearing lubrication and belt tension<\/td><td>Quarterly<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Cutting galvanized sheet generates large amounts of zinc-oxide fume, significantly increasing the load on the extraction system and sharply shortening filter life. Inspect more frequently in this case.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">9. Common Maintenance Misconceptions<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Misconception<\/th><th>Reality<\/th><\/tr><\/thead><tbody><tr><td>&#8220;If the lens still works, don&#8217;t replace it.&#8221;<\/td><td>A contaminated lens raises energy consumption and damages the nozzle as well.<\/td><\/tr><tr><td>&#8220;Tap water is fine for the chiller.&#8221;<\/td><td>Scaling causes cooling failure; repair costs far exceed the cost of water.<\/td><\/tr><tr><td>&#8220;Nozzles are cheap, so replace them casually.&#8221;<\/td><td>Replacing without recalibration amplifies quality problems.<\/td><\/tr><tr><td>&#8220;Guide rails are covered, so they need no attention.&#8221;<\/td><td>Chips penetrate the cover gaps; regular cleaning is required.<\/td><\/tr><tr><td>&#8220;Maintenance hurts capacity; do it when we&#8217;re idle.&#8221;<\/td><td>Two hours of planned maintenance prevents two days of unplanned downtime.<\/td><\/tr><tr><td>&#8220;The extraction system doesn&#8217;t affect cutting.&#8221;<\/td><td>Fume contaminates lenses and directly causes power attenuation.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">10. Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Laser cutting machine maintenance looks unglamorous but pays off measurably. Its real value is not a clean-looking machine; it is holding cutting quality at a consistent level and keeping wear-part cost and downtime to a minimum.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Minshuo Smart Manufacturing operates a three-tier system of shift checks, weekly maintenance, and quarterly deep maintenance. Every machine has its own maintenance record card, and lens, nozzle, and filter replacements are all logged. We recommend that users establish the same mechanism: make maintenance a system rather than a response to breakdowns.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><em>The maintenance intervals and parameters in this article are general industry reference values. Requirements differ among machine brands; follow the manufacturer&#8217;s manual and actual operating conditions.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The processing capability and operating cost of a laser [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[108],"tags":[],"class_list":["post-395","post","type-post","status-publish","format-standard","hentry","category-laser-cutting"],"_links":{"self":[{"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/posts\/395","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/comments?post=395"}],"version-history":[{"count":1,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/posts\/395\/revisions"}],"predecessor-version":[{"id":396,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/posts\/395\/revisions\/396"}],"wp:attachment":[{"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/media?parent=395"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/categories?post=395"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.eoil.com\/index.php\/wp-json\/wp\/v2\/tags?post=395"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}